Edwards Signaling manufacturers a complete line of audible and visual signals for industrial and commercial applications. Products include: fire alarm control panels, flashing and steady LED and halogen beacons and lights, strobes, vibrating horns and bells, outdoor warning sirens, public address and intercom systems, LED message centers and electronic system signals. Adt smoke alarm setup guide printer’s instructions: manual,quick start,nova,smoke - nortek p/n: 10015711b- ink: black plus pms 286c - material: 105g coated paper - size: 105mm x 105mm - scale: 1-1 - binding: trim, fold and saddle stitched - page 1 of 34.
E-FSC Series
Conventional Fire Alarm Control Panels
Description
Note: E-FSC series panels have been replaced by FX series conventional panels (FX-5 and FX-10)
|
Link to this product
for email:
For web page (with image): |
Catalog Numbers
Catalog Number | Description |
Specifications
Approvals
Agency ApprovalsSpecifications
E-FSC1004 Series
- Power Supply: 4.25 amps expandable to 8.5 amps
- NAC Voltage Rating: 24V FWR
- Maximum NAC current: 2.0 amps each, 3.5 amps total; 7.0 amps w/ optional transformer
- AC Input
- 120V AC 50/60 Hz: 2.2 amps w/ optional transformer
- Base Panel Current Draw
-
- Standby: 128 mA
- Alarm: 242 mA
- Panel Battery Charge Capacity (sealed lead acid only): Up to two 24 Ah batteries, 10 Ah in cabinet
- Auxiliary Current: 0.5 amps max. May be programmed as resettable.
- Auxiliary Output: 21.2 to 25.7 Vdc
- IDC Alarm Current: 3.0 mA (Consult detector compatibility list p/n 3100468 for maximum detectors per circuit)
- IDC Circuit:
- Maximum loop resistance: 13 Ohms
- Maximum loop capacitance: 0.03 microF
- IDC Operating Voltage: 16.3 to 28 Vdc
- UL Detector ID: 100
- Alarm Contact (Form C): 30 Vdc @ 1 A (resistive load)
- Trouble Contact (Form C): 30 Vdc @ 1 A (resistive load)
- Supervisory Contact (Form C): 30 Vdc @ 1 A (resistive load)
- Operating Environment
- Temperature: 32 - 120F (0 - 49C)
- Humidity: 5 - 93% RH, non-condensing
- Terminals (wire gauge): 18 - 12 AWG (0.75 mm² - 2.5 mm²)
- Asynchronous Serial Communications
- Maximum resistance: 13 Ohms
- Maximum capacitance: 0.03 microF
E-FSC502 Series
- Power Supply: 4.25 amps total
- NAC Voltage Rating: 24V FWR
- Maximum NAC current: 2.0 amps each, 3.5 amps total
- AC Input
- 120V AC 50/60 Hz: 1.25 amps
- Base Panel Current Draw
-
- Standby: 104 mA
- Alarm: 224 mA
- Panel Battery Charge Capacity (sealed lead acid only): Up to 24 Ah, 7Ah max in cabinet *
- Auxiliary Current: 0.5 amps max. May be programmed as resettable.
- Auxiliary Output: 21.2 to 25.7 Vdc
- IDC Alarm Current: 3.0 mA (Consult detector compatibility list p/n 3100468 for maximum detectors per circuit)
- IDC Circuit:
- Maximum loop resistance: 13 Ohms
- Maximum loop capacitance: 0.03 microF
- IDC Operating Voltage: 16.3 to 28 Vdc
- UL Detector ID: 100
- Alarm Contact (Form C): 30 Vdc @ 1 A (resistive load)
- Trouble Contact (Form C): 30 Vdc @ 1 A (resistive load)
- Supervisory Contact (Form C): 30 Vdc @ 1 A (resistive load)
- Operating Environment
- Temperature: 32 - 120F (0 - 49C)
- Humidity: 5 - 93% RH, non-condensing
- Terminals (wire gauge): 18 - 12 AWG (0.75 mm² - 2.5 mm²)
- Asynchronous Serial Communications
- Maximum resistance: 13 Ohms
- Maximum capacitance: 0.03 microF
E-FSC302 Series
- Power Supply: 4.25 amps total
- NAC Voltage Rating: 24V FWR
- Maximum NAC current: 2.0 amps each, 3.5 amps total
- AC Input
- 120V AC 50/60 Hz: 1.25 amps
- Base Panel Current Draw
-
- Standby: 96 mA
- Alarm: 180 mA
- Panel Battery Charge Capacity (sealed lead acid only): Up to 24 Ah, 7Ah max in cabinet *
- Auxiliary Current: 0.5 amps max. May be programmed as resettable.
- Auxiliary Output: 21.2 to 25.7 Vdc
- IDC Alarm Current: 3.0 mA (Consult detector compatibility list p/n 3100468 for maximum detectors per circuit)
- IDC Circuit:
- Maximum loop resistance: 13 Ohms
- Maximum loop capacitance: 0.03 microF
- IDC Operating Voltage: 16.3 to 28 Vdc
- UL Detector ID: 100
- Alarm Contact (Form C): 30 Vdc @ 1 A (resistive load)
- Trouble Contact (Form C): 30 Vdc @ 1 A (resistive load)
- Supervisory Contact (Form C): 30 Vdc @ 1 A (resistive load)
- Operating Environment
- Temperature: 32 - 120F (0 - 49C)
- Humidity: 5 - 93% RH, non-condensing
- Terminals (wire gauge): 18 - 12 AWG (0.75 mm² - 2.5 mm²)
- Asynchronous Serial Communications
- Maximum resistance: 13 Ohms
- Maximum capacitance: 0.03 microF
Documentation
Quick Star Fire Alarm Manual Free
Brochures
- Fire Alarm Life Safety Product Guide.pdf
A guide for the Edwards fire alarm products, including the E-FSC conventional panels, E-FSA addressable panels, initiating devices, signaling devices, and accessories.
Catalog PagesData SheetsFire Alarm Sales Tools
- Fire Alarm FAQs_v2.pdf
This contains a list of commonly asked questions (with answers) regarding fire alarm systems.
- NAC Load_Wiring and dB_Calcs_V8.xls
This spreadsheet will help calculate signal circuit loads, wire distances, and dB loss for speaker circuits.
- E-FSC Panel Battery Calculations
Battery calculations for the E-FSC conventional fire alarm panels.
- 85001-0541-E--Strobe Handbook.pdf
A guide to the application and installation of fire alarm strobe devices.
Installation InstructionsOtherTechnical Bulletins
- Tech Bulletin TF00003E
AC Power Fail May Cause NACs to Turn Off
- Tech Bulletin 090811-2 Dialer Troubleshooting.pdf
Tips on troubleshooting problems with dialers.
- AE_Bull_011513_Dialers_Internet_Cell.pdf
This bulletin provides tips for using Edwards dialers with TCP/IP internet and GSM (cellular phone) interface devices used for connecting to central monitoring stations.
- AE Bulletin, Door Holders and Fire Alarm
Tips on how to connect door holders to fire alarm systems.
Installation and User Guides
Instructions and manuals are best downloaded from our individual product pages via the menu bar above. However, for your convenience, the main instructions for each of C-TEC's product ranges (typically our control panel manuals) can be downloaded via the menus below. If you cannot find what you are looking for either here or on our product pages please contact our marketing team at marketing@c-tec.co.uk
CFP Economy Panel Installation Manual
Download
CFP Universal User Manual
Download
EP203 Extinguisher Panel Short Form Install Manual
Download
EP203 Extinguisher Panel Main Install Manual
Download
XFP 1 Loop 16 Zone Panel Engineering Manual
Download
XFP 1/2 Loop 32 Zone Panel Engineering Manual
Download
Manual Fire Alarm System Definition
XFP Universal User Manual/Log Book
Download
Quick Star Fire Alarm Manual Pdf
ZFP Engineering Manual
Fire Alarm Installation Manual
Download
ZFP User Manual/Log Book
Download
PC Serial Comm Port setup for C-TEC Control Panels
Download
Please visit our Power Supply product pages to download the instructions for this range of products.
ECU4/8/16 Engineering Manual
Download
Please visit our Conventional Call System product pages to download the instructions for this range of products.
QT601/2 Quantec Controller Engineering Manual
Quick Star Fire Alarm Manual Download
Download
PC Serial Comm Port setup for C-TEC Control Panels
Download
Please visit our Induction Loop System product pages to download the instructions for this range of products